Best case
Payback
Run a layered wall or reopen a saved study. Compare a revision and download the evidence.
Study file
Start with the bare wall, or import your evidence.
Run the bare wall, pin it as your baseline, then load and run the insulated example.
| Depth (mm) | Temperature (°C) |
|---|
Compare up to five thicknesses with the same conductivity, wall area and face temperatures.
| Thickness (mm) | Heat transfer (W) | Resistance (m²·K/W) |
|---|
Recalculate 2–12 saved evidence files locally. Each row uses the saved current run. The first study is the reference for comparisons.
Choose JSON evidence files up to 64 KiB each.
Negative values flow inward. Positive values flow outward. Percentages compare magnitude against the reference only when area and face temperatures match.
| Study | Inside / outside (°C) | Area (m²) | Heat transfer (W) | Heat flux (W/m²) | Resistance (m²·K/W) | Reduction vs reference | Saved results |
|---|
Open a saved study and vary one layer across up to 36 combinations. Set a heat-flow target to find the thinnest tested option. Add your prices, labour, waste and delivery to find the cheapest installed option. Use your tariff and operating hours to estimate annual savings and payback. Add maintenance, tariff increases and discounting to compare lifetime cost. Schedule replacements, apply a residual credit, and compare best, base and worst assumptions.
Choose an evidence JSON file up to 64 KiB.
Discounted cost range across cases
Chart labels follow your assumptions. Discounted payback is the first year end after which savings stay at or above zero through the study.
Open markers on the savings chart show discounted payback.
Compare today’s value of installation, energy and scheduled cash flows.
Payback is the first year end after which discounted savings stay at or above zero through the study. Maintenance stays fixed in nominal currency. Replacement expenses and end-of-study residual credits count when entered.
◆ Replacement · ◯ Residual credit · Vertical guides include saved-wall events
Compare upfront cost and annual savings against the saved wall.
Estimates use steady heat flow, a flat tariff and constant annual hours. The chart excludes maintenance, financing and tariff changes.
| Run | Cost rank | Thickness (mm) | Conductivity (W/(m·K)) | Heat flow (W) | Material cost | Budget remaining | Eligibility |
|---|
Dashed line is the target. Blue points meet it. Select a point to inspect that run.
Ranked by thickness, then lower heat flow. Frontier options cannot be beaten on both thickness and heat flow within this grid. The cutaway uses the modelled wall depth and layer temperatures.
| Run | Rank | Thickness (mm) | Conductivity (W/(m·K)) | Heat flow (W) | Margin (W) | Trade-off |
|---|
Negative watts flow inward. Each cell compares heat-flow magnitude with the saved study. Darker cells indicate larger magnitudes.
Model and assumptions
The solver adds each layer’s thickness divided by its conductivity. Dividing the face temperature difference by the total resistance gives heat flux. Multiplying by wall area gives heat transfer. Negative values mean heat moves from outside to inside.
Use this as a first-pass comparison for envelope design, insulation studies or teaching. The inputs stay in your browser and exports include both runs, the method, the units and the solver’s version.
The calculation assumes flat, uniform layers and known wall-face temperatures. It excludes air films, thermal bridges, moisture and thermal storage. Example conductivities are illustrative.
Read the U.S. Department of Energy’s explanation of layered resistanceResearch and engineering teams
Use the sample evidence to check your implementation or teach sensitivity analysis. It records the material inputs, boundary conditions, results and solver fingerprint. The RiverFlow source shows the checked arithmetic that sums the layer resistances.
In the terminal, run node rf2-thermal.mjs rerun saved.json. Add a revision JSON as the second argument to compare it with the imported study. For several studies, use node rf2-thermal.mjs batch first.json second.json to write CSV. For a parameter grid, use node rf2-thermal.mjs sweep saved.json sweep.json. Use node rf2-thermal.mjs target saved.json target.json to rank tested options for a heat-flow target. Run node rf2-thermal.mjs cost saved.json cost.json to compare costs and budget. Use node rf2-thermal.mjs installed saved.json installed.json for the installed cost breakdown. Run node rf2-thermal.mjs energy saved.json energy.json for annual savings and payback. Run node rf2-thermal.mjs lifecycle saved.json lifecycle.json for discounted lifetime cost. Use renewal.json from the kit to include replacements and residual value. Run node rf2-thermal.mjs sensitivity saved.json sensitivity.json for best, base and worst scenarios. The kit includes a local MCP server and setup instructions.
Bring an engineering question and a reference result. SFE can scope a browser-based study with a documented model, an acceptance check and a handover your team can reproduce.
Scope a research workflow